Autotrol i Manual – Free download as PDF File .pdf), Text File .txt) or read online for free. Valve Exploded View. Valve Parts List. Performa Exploded View. Performa Parts List. Logix Series Controllers Parts List. TROUBLESHOOTING. SWT’s online PDF library of Autotrol Control Valve Installation, Operation, Logix Operation Manual (Models: Twin Alternating, Twin.

Author: Dira Kazibar
Country: Luxembourg
Language: English (Spanish)
Genre: Literature
Published (Last): 1 September 2005
Pages: 363
PDF File Size: 15.28 Mb
ePub File Size: 17.5 Mb
ISBN: 793-1-84949-264-8
Downloads: 37023
Price: Free* [*Free Regsitration Required]
Uploader: Shakajinn

It sounds as if you need a set of new flapper valves, especially the brine pair.

Thanks for all the helpful advice. I’ve never seen a bad ball. I remember seeing it in the old manuals where it showed a check manyal but no real clear way to get to it. All times are GMT If the ball doesn’t seal against its seat you may get water into the salt tank.

Autotrol | Water Softener Manuals

The only “check valve” is the black rubber ball in the air check on the right side facing the control. Originally Posted by kpreilly.

So I will get a rebuild kit and try that. Any advice would be greatly appreciated! In what area is the zutotrol valve and is there anything that it can be soaked in to clean it out like Iron out. After putting it back together and installing it back on the tank it still won’t 525 brine and actually water comes out of the brine well tube.

  DEPAPILLATION OF TONGUE PDF

Water Softener Manual | Autotrol | Aqua Tech Water

I’ve cleaned the little screen and the injector – and I’ve cleaned the air mnual valve base. The time now is I also have an Autotrol – and the brine tank is consistently overfilling.

Autotrol won’t draw brine Printable View. I manuql was going to buy a rebuild kit but don’t want to waste the money if I need to replace the valve assembly. I have soaked it in Iron out, flushed it, cleaned the flapper valves, screen, injector valve basically everything that can come apart has come apart and been cleaned. It sounds like there is leakage past the 2 and possibly the 3 flapper valves and these are the two main valves.

I have taken the control valve off numerous times, disassembled it and cleaned it as best I can.

I replaced all the flapper valves and everything works fine now. I will let you know the results, thanks.

I have an Autotrolthe problem I am having is it is not drawing brine in fact during the brine cycle it flows a small amount of water into the brine tank instead of creating the suction mamual to manial brine out of the tank.

Can you hear the valve move if you shake the valve body? The Autotrol part number of ATthe valve body that sets on top of the tank adapter module looks to be around When it is free anyway. Is there anything inside the valve that I cannot get to that might be clogged or 525 and if so what can I do about it? I have a steady, but slow stream of water little more than a trickle coming through the drain line.

  IGCSE CAMBRIDGE INTERNATIONAL MATHEMATICS 0607 EXTENDED PDF

Osmonics/Autotrol Manuals

With all of the flappers and other parts off one might be able to by soaking it in some thing like iron out. The air check is where the brine line going to the salt tank is connected to the control valve on top the air check. What kind of water quality are you deal with? There is no check valve anywhere inside the Autotrol If I need one do you have a valve that can be rebilt, or how much is a new valve without the timer. I will have to check one of the valves that I have in the pile, see what it sounds like.

You don’t need any new module etc.

While looking at the parts brake down of that valve, I see that there are some O rings between the two parts. Yes I agree, I disassembled the valve, again, and soaked everything in a concentrated solution of Iron out and it is clean.

My main problem is iron, I thought about soaking it in a heavy concentrate of super iron out for a couple of days.