HACMP TROUBLESHOOTING GUIDE PDF

SexLeave a Comment on HACMP TROUBLESHOOTING GUIDE PDF

HACMP TROUBLESHOOTING GUIDE PDF

Problem determination PowerHA / HACMP. Collect logs: clsnap -d ‘/tmp’ -p2 -n ‘ node1,node2’. or. snap -e. If cspoc pb: /tmp/ <= more details. Hi, I have a running HACMP Cluster with two nodes. Its working in also check out this troubleshooting guide. Checking the TCP/IP Subsystem. This is the basic requirement for HACMP cluster configuration. The verification Which are the HACMP log files available for troubleshooting?.

Author: Nikomi Gardam
Country: Bolivia
Language: English (Spanish)
Genre: Politics
Published (Last): 27 October 2015
Pages: 281
PDF File Size: 17.8 Mb
ePub File Size: 18.40 Mb
ISBN: 377-3-68402-585-7
Downloads: 80252
Price: Free* [*Free Regsitration Required]
Uploader: Nizil

Also for all the resource groups on the Active node please specify the passive node as the next node in the priority to take over in the event of failure of active node. Then read back through the log file to the first message relating to that problem.

The verification process does not allow the IP addresses to be in same subnet and cluster will not start. This configuration will be useful if there is a failure of single Oracle Database instance on one node to be failed over to another node without disturbing other running Oracle instances.

  BESTIARIUSZ SOWIASKI PDF

Guide to IBM PowerHA SystemMirror for AIX Version 7.1.3

Each hackp is identified by a number appended to the file name. Many error messages cascade from an initial error that usually indicates the problem source.

Using cluster log files. The following sections describe the types of messages output by the PowerHA SystemMirror software and the log files into which the system writes these messages. Posted by Vineet at 7: The event summaries included in this log make it easier to see quickly what events have occurred recently in the cluster.

These messages provide valuable information for understanding the current state of the troubleshopting. The individual logs are limited to a maximum size and are removed after they reach a certain age, or are overwritten by newer versions. troublehooting

Guide to IBM PowerHA SystemMirror for AIX Version [Book]

Newer Post Older Post Home. Each log file contains a different subset of messages generated by the PowerHA SystemMirror software.

guie Can multiple Service IP addresses be configured on single Ethernet cards? Following are log files which can be used for troubleshooting: Reviewing cluster message log files The PowerHA SystemMirror software writes the messages it generates to the system console and to several log files.

When checking this file, first find the most recent error message associated with your problem.

  BATTLETECH TECHNICAL READOUT PROTOTYPES PDF

My survival notes : Problem determination PowerHA / HACMP

For this one needs to have separate Service IP addresses over which the listeners for every Oracle Database will run. Resource group handling has been enhanced in recent releases and the hacmp.

The Volume mounted over NFS protocol is a file system for AIX, and since disk device is required for Enhanced concurrent capable volume group for disk heartbeat the NFS file system cannot be used for configuring the disk heartbeat. Understanding the system error log The PowerHA SystemMirror software logs messages to the system error log whenever a daemon generates a state message. Hence one can have separate Resource groups which will own each Oracle instance.

When viewed as a group, the log files provide a detailed view of all cluster activity. The hostname cannot have guuide characters: For instance, the hacmp. The system cycles hacmp.